Pollution Protection Systems
- Home
- Pollution Protection Systems
Pollution Protection Systems Mumbai Pvt. Ltd (PPS) Company established in “1994”. PPS Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPS also provides solutions related to Gas Detection & Flame Detection.
PPS serves the growing demands of industries like Chemicals, Oil, Gas & Petrochemicals, Pharmaceuticals, Steel, and Refineries as well as major Capital industries. PPS aims to provide unique service levels to our customers by continuously improving our ability to assess and surpass their needs.
Our Company’s work is based on integrated equipment of customer’s facilities with systems of Fire and Gas Detection, including:
- Projecting of the given systems subject to integration in systems of industrial control and separately
- Manufacturing and supply of the given systems
- Mounting, starting-up and adjustments
- Warranty and after sales services
- And Calibration
Our Product range includes:
- Continuous Gas Monitoring System (For Toxic/ Combustible & Oxygen)
- Fixed Fire & Gas Monitoring and Detection Systems.
- Open Path Gas Detectors.
- Heat and Water Detection.
- Portable Gas Detectors.
- Explosion-proof Sounders, Beacons, Loudspeakers and Call Points
Fixed Gas Monitoring Systems
- Conventional Modular Fixed Gas Monitoring System (CMF-GMS)
- Intelligent Modular Fixed Gas Monitoring System (IMF-GMS)
- Scanner Based Fixed Gas Monitoring System (SBF-GMS)
- Stand Alone Fixed Gas Monitors + (SAF-GM)
Smoke/Fire Alarm & Detection Systems
Toxic Gas Detector
Model gaZsens Txi is dual safety device having combination of flame proof, weather proof certified (Ex’d’) sensor housing & intrinsically safe (Exia) transmitter by CIMFR, Dhabad (formerly known as CMRI), to be use in hazardous area for detection of Toxic gases like H2S, NH3, Cl2, & many more
- CIMFR certified. Designed to flameproof as per IS 2148:2004 (IEC60079-1/2001) & Weatherproof as per IS 12063-1987 (IEC 60529-1989) for use in hazardous area application.
- IP 55 sensor housing with a choice of threads. Flexibility for all installations.
- Electrochemical cell sensing technology. Proven, fast, reliable with a typical life of 2 years.
- Easy maintenance. Exchangeable electrochemical cells while powered.
Flame detectors UV/IR, IR3
All the detectors are supplied with implosion protection, has digital addressable output RS-485, current output 4-20mA and relay output. It makes possible to connect the detectors to any monitoring and receiving fire controller.
Specifications:
- Detection Range : nom. up to 30m @ 1ft-sq n-heptane fires.
- Field of View : 90°.
- Response Time : typical 3 to 5 sec.
- Input Rating : 24VDC (11V to 32V).
- Outputs : Relay Contacts(Alarm/Fault) / 4-20mA current(stepped).
- Enclosure(optional) : Aluminium with anodizing finish.
- Dimensions / Weight : 83(D)X126(L)mm / 1.1kg.
- Certifications : ATEX approved(by DNV) /CE-marking
Single / Multi Gas Monitoring
- Power Supply Card: Size - 220 mm X 100 mm Supplies Power (9 V DC to 24 V DC) to complete system including gas detector assembly (Field Unit) with a current carrying capacity of one card is maximum up to 5 Amp. This can cater up to 10 cards in one rack. Multiple numbers of cards in multiple numbers of Racks in one panel can be provided if the numbers of channels are more than ten.
- Control card: Control card provides fixed voltage & current required to the field unit. It also accepts 4-20 mA signal from field unit. This signal is then processed by control card using instrumentation amplifier. The processed signal corresponding to the gas concentration available in the field is displayed by two or three digit 7 segments LED on control card display section. The control card also delivers 4-20 mA.(repeater) output Signal for PLC / DCS.
- Facility Card: This card receives the alarm condition signal from control card. Depending upon the alarm conditions it activates the relays mounted on it & hoots the buzzer or siren or sends control signal to the pre-desired device. It also consists of alarm ACCEP, RESET & LAMP TEST conditions. The Push buttons are provided on the fascia plate to achieve the desired job.
- Mother Board: This board is provided on the back of 19” rack. The Mother Board PCB is provided with the copper tracks & Euro Connectors to hold all the cards like Control Card, Power Supply Card & Facility card. With the help of proper design reduces the back panel wiring of all cards
OPEN PATH GAS DETECTORS
- ELDS OPGD for Methane Detection
- ELDS OPGD for Methane & H2S (Combined)
- ELDS OPGD for Toxic Gas Detection
- ELDS OPGD for HVAC Duct Application
Hazardous Area Signalling
- Explosion-proof Sounders, Beacons, Loudspeakers and Call Points
Portable Gas Detectors
- Portable Single/Multi Gas Monitor
- Portable Combustible Gas Monitor
- Portable Toxic Gas Monitor
- Hand-Held Laser Remote Gas Leak Detector
For Enquiries
Contact Person : Mohammed Asharaf
Contact No. : 00971-50-4456510, Email : sales@experts-ei.com